B.Braun LogoB.Braun Logo
    • Solutions

      • B2B & Industry Partners
      • Smart Infusion Management
      • Surgical Asset & Supply Management
      • Technical Service
    • Therapies

      • Extracorporeal Blood Treatment Therapies
      • Infusion Therapy
      • Interventional Vascular Therapy
      • Minimally Invasive Surgery
      • Neurosurgery
      • Nutrition Therapy
      • Oncology
      • Pain Therapy
      • Spine Surgery
      • Surgical Instruments & Sterile Container Systems
      • Surgical Power Systems
      • Sutures & Surgical Specialties
    Find the product you are looking for. Visit the B. Braun product catalog with our complete portfolio. 

    Product Catalog

    Find the product you are looking for. Visit the B. Braun product catalog with our complete portfolio. 

    • We coordinate your medical care when discharged from the hospital. For more information, please visit our home care page.

      Home Care

      We coordinate your medical care when discharged from the hospital. For more information, please visit our home care page.

      A planned hospitalization can affect anyone. Did you know that you as patient can do a lot for your own safety and that of other patients? 

      Hygiene & Health

      A planned hospitalization can affect anyone. Did you know that you as patient can do a lot for your own safety and that of other patients? 

      • Our Culture

        • Working at B. Braun
      • Your Opportunities

        • Work and career
        • Your Benefits
      Discover your career opportunities at B. Braun. Search our global job market for interesting job profiles. 

      Find Your Job

      Discover your career opportunities at B. Braun. Search our global job market for interesting job profiles. 

      • Company

        • Brand
        • Facts & Figures
        • Innovation Hub
        • Vision & Values
      • Contact

        • Contact Form
        • Grievances
        • Locations
      • Media

        • Press Releases
      • Responsibility

        • Access to Health Care
        • Compliance
        • Diversity
        • Sponsoring & Donations
        • Sustainability
      Let us drive innovation in medical technology together. Learn more about our innovation hub and present your idea.

      Innovation Hub

      Let us drive innovation in medical technology together. Learn more about our innovation hub and present your idea.

      In dialog with B. Braun. Get in touch with us.

      Contact

      In dialog with B. Braun. Get in touch with us.

    • Products & Solutions
      • Solutions
        • B2B & Industry Partners
        • Smart Infusion Management
        • Surgical Asset & Supply Management
        • Technical Service
      • Therapies
        • Extracorporeal Blood Treatment Therapies
        • Infusion Therapy
        • Interventional Vascular Therapy
        • Minimally Invasive Surgery
        • Neurosurgery
        • Nutrition Therapy
        • Oncology
        • Pain Therapy
        • Spine Surgery
        • Surgical Instruments & Sterile Container Systems
        • Surgical Power Systems
        • Sutures & Surgical Specialties
    • Career
      • Our Culture
        • Working at B. Braun
      • Your Opportunities
        • Work and career
        • Your Benefits
    • About us
      • Company
        • Brand
        • Facts & Figures
        • Innovation Hub
        • Vision & Values
      • Contact
        • Contact Form
        • Grievances
        • Locations
      • Media
        • Press Releases
      • Responsibility
        • Access to Health Care
        • Compliance
        • Diversity
        • Sponsoring & Donations
        • Sustainability
    Language country combination selection page
    India
    • Imprint
    • Terms of use
    • Privacy Policy

    Not all products are registered or approved for sale in every country or region, and indications for use may vary by location. For information on product availability and approved uses, please contact your local B. Braun representative. Product images are provided for general reference only and do not represent specific product effects or features. All content on this website is provided on an “as is” and “as available” basis. The company disclaims all warranties of any kind—express, implied, statutory, or otherwise—including, without limitation, implied warranties of merchantability, fitness for a particular purpose, non-infringement, and the accuracy, completeness, or reliability of any content available through this website. Unless otherwise stated, all content, product names, and service names appearing on this website are protected by copyright, trademark, and other applicable intellectual property rights owned by or licensed to B. Braun, its subsidiaries, or affiliates. Such materials may not be redistributed, duplicated, or disclosed, in whole or in part, without the prior express written consent of B. Braun Medical (India) Pvt. Ltd.

    Copyright © B. Braun Medical (India) Pvt. Ltd. - version 1.51.1
    • Home
    • Orthopaedic Surgery
    • Knee Arthroplasty
    • VEGA System®

    Product Picture Enlargement CW-VEGA System®
    Product Picture Web Enlargement-VEGA System®
    Product Picture Web Enlargement-VEGA System®
    Product Picture Web Enlargement-VEGA System®
    Product Picture Enlargement CW-VEGA System®
    Product Picutre Enlargement CW-VEGA System®
    Product Picture Enlargement CW-VEGA System®
    Product Picture Enlargement CW-VEGA System®
    Product Picture Enlargement CW-VEGA System®
    Product Picture Web Enlargement-VEGA System®
    Product Picture Web Enlargement-VEGA System®
    Product Picture Web Enlargement-VEGA System®
    Product Picture Enlargement CW-VEGA System®
    Product Picutre Enlargement CW-VEGA System®
    Product Picture Enlargement CW-VEGA System®

    VEGA System®
    Posterior stabilized system for natural rotation

    The posterior stabilized VEGA Knee System was developed to fulfill the modern-day requirements of patient and surgeons for a modern knee implant system. The following objectives were considered in its design:

     

    Natural kinematics through a rollback and a pivotal motion around the medial condyle


    During flexion, the natural knee shows increased rollback of the femur on the lateral side while the femur rotates around the medial center.[1] The asymmetric cam design of VEGA facilitates this lateral rollback and medial rotation, and therefore enables a natural pivotal motion.[2]

     

    Stability even in high flexion
     

    Based on the design and the position of the PS box and post, the contact point of the box and post move distally with an increase of flexion. Therefore the increased jumping distance in flexion can reduce the subluxation risk. The synchronized contact surfaces between the articulating components maximize the bearing surface stress distribution in extension, reducing the risk of delamination. The high congruency between femur and tibia in extension as well as the line contact up to 160° of flexion stabilizes the patient’s movements and reduces wear. To reach higher varus-valgus stability a PS+ gliding surface with a mediolaterally wider PS post is available. Posterior inclination of the post design prevents anterior impingement with the extensor mechanism and increases resistance to dislocation.

     

    Soft tissue friendly and bone sparing implant design [2]
     

    Besides the reconstruction of natural kinematics, two attributes were in the foreground during the development of the VEGA Knee System. A soft tissue friendly design as well as the reduction of bone loss. 13 femur sizes, including standard and narrow sizes, and 11 tibial sizes, including standard and AP+ sizes, offer a wide range for a better bone fit regardless of gender, size, morphotype or race. Additionally, the VEGA System®’s narrow low-profile box helps to preserve bone and results in stable patellar tracking. A short tibial stem design as well as slim tibial wings support the bone sparing philosophy of VEGA. Furthermore the curved wing design facilitates a high rotational stability.

     

    Long-term performance through innovative materials 
     

    Advanced Surface: Wear is the number one reason for long-term knee replacement revisions.[3] To combat this issue, the AS coating can deliver up to a 65 % reduction in wear when compared to a CoCr prosthesis, as demonstrated in testing with other Aesculap knee designs. Furthermore, with the AS coating metal ion concentrations remain low and are below any biological threshold. This makes the AS coated implants an ideal solution for patients who are allergic to metal. The AS multilayer coating reduces the hardness from top to bottom in a gradient-like fashion, resulting in an improved elastic modulus. This makes it stable against mechanical stresses and strains.[4-7]

    Beta Polyethylene: All of Aesculap’s polyethylenes are sterilized under Beta radiation, which reduces oxidation, decelerates the aging process, and yields better wear rates.[8-10]

     

    Easy handling and precise results with the new generation of IQ instruments as well as the OrthoPilot® Navigation System

    • Patient specific with OrthoPilot® Navigation
    • User-friendly with IQ Instruments
    Read more

    References

    [1] Pinskerova V, Johal P, Nakagawa S, Sosna A, Williams A, Gedroyc W, Freeman MA. Does the femur roll-back with flexion? J Bone Joint Surg Br. 2004 Aug;86(6):925-31.
    [2] Mihalko WM. Knee Computer Simulation Analysis of the VEGA Total Knee to DePuy PFC Sigma and Zimmer LPS. Tennesse, 2013.
    [3] Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM. Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res. 2002 Nov;(404):7-13.
    [4] Reich J, Hovy L, Lindenmaier HL, Zeller R, Schwiesau J, Thomas P, Grupp TM. Präklinische Ergebnisse beschichteter Knieimplantate für Allergiker. Orthopäde. 2010 Mai;39(5):495-502.
    [5] Affatato S, Spinelli M, Lopomo N, Grupp TM, Marcacci M, Toni A. Can the method of fixation influence the wear behaviour of ZrN coated unicompartmental mobile knee prostheses? Clin Biomech (Bristol, Avon). 2011 Feb;26(2): 52-8. Epub 2010 Oct 8.
    [6] Grupp TM, Schwiesau T. Determination of the wear behaviour of the univation mobile knee system T018, Mar 2007.
    [7] Harman MK, Banks SA, Hodge WA. Wear analysis of a retrieved hip implant with titanium nitride coating. J Arthroplasty. 1997 Dec;12(8):938-45.
    [8] Griffin W et al. Modular insert exchange in knee arthroplasty for treatment of wear and osteolysis, Clinical Orthopaedics and related research, No. 464, 2007, S. 132-137.
    [9] NN. What modifications can be made to materials to improve wear behaviour. American Academy of Orthopaedic surgeons. 2001. S. 196.
    [10] Aesculap Orthopaedics. Die Premium Knieendoprothese, wissenschaftliche Information, Nummer O36801, 2009.